Accessories

Valve heads - for rotary valves

Other configurations are available upon request.

Valve heads from the DISTRIBUTION series can also be used with syringe pumps.

previous arrowprevious arrow
next arrownext arrow
Slider

DISTRIBUTION series

6 ports, 0.5mm channels
Ref: VD1-6-050

Carryover volume: 1.5 μl
Internal volume: 2.5 μl

previous arrowprevious arrow
next arrownext arrow
Slider

ON/OFF series

2 ports, 0.75mm channels
Ref: VO1-2-075

Carryover volume: 1 μl
Internal volume: 3 μl

previous arrowprevious arrow
next arrownext arrow
Slider

DISTRIBUTION series

8 ports, 0.5mm channels
Ref: VD1-8-050

Carryover volume: 1.5 μl
Internal volume: 2.5 μl

previous arrowprevious arrow
next arrownext arrow
Slider

SWITCH series

4 ports, 0.5mm channels
Ref: VS1-4-050

Carryover volume: 0.55 μl
Internal volume: 2.5 μl

previous arrowprevious arrow
next arrownext arrow
Slider

DISTRIBUTION series

8 ports, 1mm channels
Ref: VD1-8-100

Carryover volume: 1.5 μl
Internal volume: 2.5 μl

previous arrowprevious arrow
next arrownext arrow
Slider

SWITCH series

6 ports, 0.5mm channels
Ref: VS1-6-050

Carryover volume: 0.55 μl
Internal volume: 2.5 μl

previous arrowprevious arrow
next arrownext arrow
Slider

ON/OFF series

2 ports, 0.5mm channels
Ref: VO1-2-050

Carryover volume: 1 μl
Internal volume: 3 μl

Valve heads - for syringe pumps

Other configurations are available upon request.

These valve heads can also be used with rotary valves.

previous arrowprevious arrow
next arrownext arrow
Slider

LOW CARRYOVER series

1 stage, 6 ports (1 x 6)
1 channel
Ref: VD1-6-050

Carryover volume: 2.6 μl
Internal volume: 3.5 μl

previous arrowprevious arrow
next arrownext arrow
Slider

LOW CARRYOVER series

1 stage, 8 ports (1 x 8)
1 channel
Ref: VD1-8-050

Carryover volume: 2.6 μl
Internal volume: 3.5 μl

previous arrowprevious arrow
next arrownext arrow
Slider

LOW CARRYOVER series

1 stage, 8 ports (1 x 8)
1 channel
Ref: VD1-8-100

Carryover volume: 10.2 μl
Internal volume: 14.1 μl

previous arrowprevious arrow
next arrownext arrow
Slider

ULTRA-LOW CARRYOVER series

2 stages, 6 ports (2 x 3)
2 channels
Ref: VD2-6-050

Carryover volume: 1.5 μl
Internal volume: 5.2 μl

Manifolds

These are examples. We can manufacture or design your own model.

Made to be mounted on an RVM body.

SWITCH series

2 stages, 12 ports (2 x 6)
2 independent channels
Ref: VD2-12

Carryover volume: 2.6 μl
Internal volume: 3.5 μl

ON/OFF series

4 stages, 8 ports
4 independent channels
Ref: VO4-8-050

Carryover volume: 1 μl
Internal volume: 3 μl

Syringes

Other configurations are available upon request.

25 μl syringe
Ref: S25-P

Plunger: PTFE
Syringe: borosilicate glass

250 μl syringe
Ref: S250-P

Plunger: PTFE
Syringe: borosilicate glass

50 μl syringe
Ref: S50-P

Plunger: PTFE
Syringe: borosilicate glass

500 μl syringe
Ref: S500-P

Plunger: PTFE
Syringe: borosilicate glass

100 μl syringe
Ref: S100-P

Plunger: PTFE
Syringe: borosilicate glass

500 μl syringe
Ref: S500-U

Plunger: UHMW-PE
Syringe: borosilicate glass

100 μl syringe
Ref: S100-U

Plunger: UHMW-PE
Syringe: borosilicate glass

1000 μl syringe
Ref: S1000-P

Plunger: PTFE
Syringe: borosilicate glass

Fluidic Kits

Quick start kit 1
Ref: K100-6

  • 6 standard flat-bottom 1/4-28 UNF connectors
  • 6 ferrules
  • 1.5m PTFE tubing: 0.5 x 1.6 (=1/16') mm
  • 1 setup guide

Quick start kit 2
Ref: K100-12

  • 12 standard flat-bottom 1/4-28 UNF connectors
  • 12 ferrules
  • 1.5m PTFE tubing: 0.5 x 1.6 (=1/16') mm
  • 1 setup guide

Tools and Spare Parts

Syringe change tool
Ref: T100

Custom-made tool to change the syringe

Plunger screw
Ref: SP100

Screw to fasten plunger to slider

Cables

Power supply
Ref: C100

Compatible with all our devices (not needed with RVM - Low Power)

Mini USB with ferrite
Ref: C101

Compatible with all our devices
 

Power supply to DB9 adaptor
Ref: C102

Required for RVM - Fast if purchasing power supply